Call Us +852 2666 2888

Welcome to StoreInfinity!

TES PROVA-803 Digital Multimeter Dual Channel

Be the first to review this product | Ask Question

PROVA-803 LCD Digital Multimeter Dual Input Channels Bandwidth 10KHz
SKU: STINF-MT-0208

Availability: In stock

$196.00
TES

FREE Express Shipping

Item location: International Warehouse

Free Ships to: Worldwide| See details

Estimated between
 

We ships within 1 day after receiving cleared payment.

Please allow additional time if international delivery is subject to customs processing. | See details

PaypalVisa/MasterCard
Bank transfer | See details

30 days money back

Paypal Pertection

Get the item you ordered or get your money back. | See details

Description

If you find inaccurate product information, welcome to Correct Errors

TES company was founded in 1988 with an initial gross investment of 1,000,000 USD and the products line was focused on low cost testers with basic functions. Tes's products are sold all over the world and that makes a big population of happy customers. If you are interested in any of our products or looking for some information, feel free to contact us directly. It will be an honor for us to serve your needs.

TES PROVA803 LCD 60,000 Counts 0.04%DC 0.2%AC 10,708 -10???~50??? -20??? ~60??? 2000M Digital Multimeter

TES PROVA803 LCD 60,000 Counts 0.04%DC 0.2%AC 10,708 -10???~50??? -20??? ~60??? 2000M Digital Multimeter

TES PROVA803 LCD 60,000 Counts 0.04%DC 0.2%AC 10,708 -10???~50??? -20??? ~60??? 2000M Digital Multimeter

TES PROVA803 LCD 60,000 Counts 0.04%DC 0.2%AC 10,708 -10???~50??? -20??? ~60??? 2000M Digital Multimeter

Ask a question about TES PROVA-803 Digital Multimeter Dual Channel:

Additional Info

Additional Info

Brand TES
Main Features
  • 60,000 count and dual input channels
  • 0.04% DC basic accuracy and 0.2% AC basic accuracy
  • Bandwidth of 10KHz(max)
  • Fast ACV, ACA response
  • Dual channels measurement similar to a dual channels DSO(V+V,V+A)
  • Hz + duty cycle dual display
  • Capacitance measurement
  • Standalone data logging of 10,708 records for both channels(803)
  • RS-232C interface
  • Application Software (Option)
  • 1/7 the cost
  • Specifications

    Range

    Resolution

    Beeper

    Overload Protection

    999.99 Ω

    0.01 Ω

    < 40 Ω ( approx )

    AC 1000V

    Frequency : (TTL) (Overload Protection AC 1000V)

    Range ( Auto )

    Resolution

    Accuracy

    1.000Hz - 2MHz

    0.0001Hz - 0.0001MHz

    ±0.005%±4dgts

    DC Voltage: (Input Impedance: 10MΩ )(Overload Protection DC 1000V)

    Range

    Resolution

    Accuracy

    60.000mV

    0.001mV

    ±0.2%±9dgts

    600.00mV

    0.01mV

    ±0.04%±6dgts

    6.0000V

    0.0001V

    ±0.04%±6dgts

    60.000V

    0.001V

    ±0.04%±6dgts

    600.00V

    0.01V

    ±0.04%±6dgts

    1000.0V

    0.1V

    ±0.08%±6dgts

    DC Current: (10A terminal is protected by a 20A fast blown, high energy fuse, and the terminal of μ A and mA is protected by 1A fast blown, high energy fuse )

    Range

    Resolution

    Accuracy

    600.00μA

    0.01μA

    ±0.4%±20dgts

    6000.0μA

    0.1μA

    ±0.2%±20dgts

    60.000mA

    0.001mA

    ±0.4%±20dgts

    600.00mA

    0.01mA

    ±0.2%±20dgts

    1.0000A

    0.0001A

    ±0.2%±20dgts

    10.000A 1

    0.001A

    ±0.6%±20dgts

    Diode Test: (open voltage 3V approx. overload protection AC 1000V)

    Range

    Resolution

    Accuracy

    Short Circuit Current

    3.0000V

    0.0001V

    ±2%±5dgts

    0.8 mA typical

    Duty Cycle: (%, TTL, 1Hz – 600KHz) (Overload Protection AC 1000V)

         

    Range

    Resolution

    Accuracy

    0.001% - 9.999%

    0.00%

    ±30d/KHz±30dgts

    10.00% - 100.00%

    0.01%

    ±3d/KHz±3dgts

       

    Resistance: ( Ω )

    Range

    Resolution

    Accuracy

    Overload Protection

    999.99 Ω

    0.01 Ω

    ±0.25%±9dgts

    AC 1000V

    9.9999K Ω

    0.0001K Ω

    ±0.15%±6dgts

    AC 1000V

    99.999K Ω

    0.001K Ω

    ±0.15%±6dgts

    AC 1000V

    999.99K Ω

    0.01K Ω

    ±0.15%±6dgts

    AC 1000V

    9.9999M Ω

    0.0001M Ω

    ±0.3%±9dgts

    AC 1000V

    40.000M Ω

    0.001M Ω

    ±1.5%±9dgts

    AC 1000V

    Capacitance: ( , auto range , and for film capacitor or better)

    Range

    Resolution

    Accuracy 1

    60.00nF

    0.01nF

    ±1.2% ± 8dgts

    600.0nF

    0.1n F

    ±2.5% ± 8dgts

    6.000 μ F

    0.001 μ F

    ±2.5% ± 8dgts

    60.00 μ F

    0.01 μ F

    ±3.0% ± 8dgts

    600.0 μ F

    0.1 μ F

    ±5.0% ± 8dgts

    Range

    Resolution

    Accuracy

    Accuracy

    Accuracy

    Accuracy

    (ACV)

    (50/60Hz)

    (45Hz-1KHz)

    (20Hz-45Hz)

    (1KHz-10KHz)

    60.000mV

    0.001mV

    ±0.2%±40dgts

    ±0.6%±40dgts

    ±1.6%±50dgts

    ±4% 40dgts

    600.00mV

    0.001mV

    ±0.2%±40dgts

    ±0.6%±40dgts

    ±1.6%±50dgts

    ±2%±40dgts

    6.0000V

    0.01mV

    ±0.2%±40dgts

    ±0.6%±40dgts

    ±1.6%±50dgts

    ±2%±40dgts

    60.000V

    0.0001V

    ±0.2%±40dgts

    ±0.6±40dgts

    ±1.6%±50dgts

    ±2%±40dgts

    600.00V

    0.001V

    ±0.2%±40dgts

    ±1.0%±40dgts

    ±1.6%±50dgts

    ±9%±40dgts

    (0-400V)

    600.00V

    0.01V

    ±0.2%±40dgts

    ±1.0%±40dgts

    ±1.6%±50dgts

    Not Specified

    (400-600V)

    1000.0V

    0.1V

    ±0.2%±40dgts

    ±4%±60dgts

    ±1.6%±50dgts

    ±4%±80dgts

    (0-400V)

    1000.0V

    0.1V

    ±0.2%±40dgts

    (45Hz-400Hz)

    ±1.6%±50dgts

    Not Specified

    (400-1000V)

    ±4%±60dgts

    Supplemental Dual Channels Specification (DC – 400Hz): The following accuracy should be added to all the listed accuracy if dual channels measurements are performed.

    ACV (Ch1)

    ±2%±(V1-V2)* 200 PPM (Ch1,Ch2)

    ±0.9%±(V1-V2)* 20PPM (Ch1,Ch2)

    ±0.2μA/V(μA,Ch2)

    ±0.5% (Ch1, Ch2)

    ±2μA/V (mA,Ch2)

    ±0.4mA/V(A,Ch2)

    ±4mV/A(mV,Ch1)

    ±9mV/A (V,Ch1)

    DCV (Ch1)

    ±0.9%±(V1-V2)*20 PPM (Ch1,Ch2)

    ±0.5% (Ch1,Ch2)

    ±0.5% (Ch1,Ch2)

    ±0.5% (Ch1,Ch2)

    AC Current: (The accuracy is specified for a single channel for 5%-100% of range for 45Hz–10KHz,average sensing, 10A terminal is protected by a 20A fast blown, high energy fuse, and the terminal of μ A and mA is protected by 1A fast blown, high energy fuse. If the AC reading is less than 100 least significant digits, it is set to zero by the unit )

    Range (ACA)

    Resolution

    Accuracy (50/60Hz)

    Accuracy(45Hz-1KHz)

    Accuracy (20Hz-45Hz)

    Accuracy (1KHz-10KHz)

    600.00μA

    0.01mA

    ±0.6%±40dgts

    ±0.8%±40dgts

    ±2%±20dgts

    ±4%±20dgts

    6000.0μA

    0.1mA

    ±0.6%±40dgts

    ±0.8%±40dgts

    ±2%±20dgts

    ±4%±20dgts

    60.000mA

    0.001mA

    ±0.6%±40dgts

    ±0.8%±40dgts

    ±2%±20dgts

    ±0.9%±20dgts

    600.00mA

    0.01mA

    ±0.6%±40dgts

    ±0.8%±40dgts

    ±2%±20dgts

    ±0.9%±20dgts

    1.0000A

    0.0001A

    ±0.6%±40dgts

    ±0.8%±40dgts

    ±2%±20dgts

    ±2.5%20dgts

    10.000A 1

    0.001A

    ±0.9%±40dgts

    ±0.9%±40dgts

    ±3.9%±20dgts

    ±2.5%20dgts

    Range

    Accuracy

    Accuracy

    Accuracy

    (ACA)

    (20Hz-45Hz)

    (1KHz-10KHz)

    (10KHz-20KHz)

    600.00μA

    ±1%±20dgts

    ±2%±20dgts

    ±1%±20dgts

    6000.0μA

    ±1%±20dgts

    ±2%±20dgts

    ±1%±20dgts

    60.000mA

    ±1%±20dgts

    ±0.5%±20dgts

    ±1%±20dgts

    600.00mA

    ±1%±20dgts

    ±0.5%±20dgts

    ±1%±20dgts

    1.0000A

    ±1%±20dgts

    ±1.5%±20dgts

    Not Specified

    10.000A 1

    ±2%±20dgts

    ±1.5%±20dgts

    Not Specified

    Size No
    Package Including
  • 1 x TES PROVA803 LCD 60,000 Counts 0.04%DC 0.2%AC 10,708 -10???~50??? -20??? ~60??? 2000M Digital Multimeter
  • 1 x Instruction Manual
  • 1 x Interface Cable
  • 2 x Test Leads
  • Warranty

     

    Reviews

    Write Your Own Review

    You're reviewing: TES PROVA-803 Digital Multimeter Dual Channel

    How do you rate this product? *

      1 star 2 stars 3 stars 4 stars 5 stars
    Value
    Quality
    Price
    • Reload captcha

    Tags

    Tags

    Use spaces to separate tags. Use single quotes (') for phrases.

    Shipping and Payments

    Shipping and handing

    Item location: International warehouse

    Shanghai, Australia, United Kingdom, Germany, United States

    Free Shipping to: Worldwide

    Asia

    China, Hong Kong SAR China, India, Indonesia, Japan, Macau SAR China, Malaysia, Philippines, Singapore, South Korea, Taiwan,Thailand, Vietnam

    Europe

    Austria, Belgium,Denmark, Finland, France, Germany, Greece, Hungary, Ireland, Italy,Netherlands, Norway, Poland, Portuga,Spain, Swaziland, Sweden, Switzerland, Ukraine,United Kingdom,Turkey

    Americas

    Canada, United States

    Oceania

    Australia,New Zealand

    Shipping and handing to Service Delivery*
    Free Shipping Worldwide Express Shipping Estimated 3-9 days

    Estimated delivery dates include our handling time, and will depend on shipping service selected and receipt of cleared payment. Delivery times may vary, especially during peak periods.

    Handing time Estimated Time
    Will usually ship within 1 business day of receiving cleared payment. Estimated time table

     

    Return policy

    After receiving the item Refund will be given as Return shipping*
    30 days Money Back We pays return shipping

    * include our handling time, and will depend on shipping service selected and receipt of cleared payment. Delivery times may vary, especially during peak periods.

     

    Payment details

    Payment metod Preferred / Accepted
    StoreInfinity payment method or Bank Transfer Paypal preferred